Описание оборудования | |
---|---|
Fiber optic sensor for glass fiber optics | |
General specifications | |
Sensor range | up to 70 mm (LMR 18-3,2-1,0-K4) |
Detection range | up to 300 mm (LME 18-2,3-0,5-K3) |
Light source | LED, 650 nm visible red light |
Light type | modulated visible red light |
Angle of divergence | 26 ° |
Optical face | frontal |
Ambient light limit | 30000 Lux |
Hysteresis | < 15 % |
Functional safety related parameters | |
MTTFd | 700 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Indicators/operating means | |
Operation indicator | LED green, flashes in case of short-circuit |
Function indicator | LED yellow, lights up with receiver lit |
Control elements | Sensitivity adjuster, light/dark switch |
Electrical specifications | |
Operating voltage | 10 ... 30 V DC , class 2 |
Ripple | 10 % |
No-load supply current | < 35 mA |
Protection class | II , rated voltage ? 50VAC with pollution degree 1-2 according to IEC 60664-1 |
Output | |
Switching type | light/dark on, switchable |
Signal output | Push-pull (4 in 1) output short-circuit protected overvoltage protected |
Switching voltage | 30 V DC |
Switching current | max. 200 mA |
Voltage drop | ? 2.5 V DC |
Switching frequency | 500 Hz |
Response time | 1 ms |
Compliance with standards and directives | |
Directive conformity | EMC Directive 2004/108/EC |
Standard conformity | |
Standard conformity | |
Standards | EN 60947-5-2 |
Approvals and certificates | |
UL approval | cULus Listed, Type 1 enclosure |
CCC approval | CCC approval / marking not required for products rated ?36 V |
Ambient conditions | |
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
Storage temperature | -30 ... 70 °C (-22 ... 158 °F) |
Mechanical specifications | |
Degree of protection | IP67 |
Connection | M12 connector, 4-pin |
Material | |
Mass | 60 g |